xref: /trunk/odf_docs/openformula-milestone-c-report.md (revision 1354dfcdad4129e7cc561fdcfbb4f6c8958f0428)
1<!--
2 Licensed to the Apache Software Foundation (ASF) under one
3 or more contributor license agreements.  See the NOTICE file
4 distributed with this work for additional information
5 regarding copyright ownership.  The ASF licenses this file
6 to you under the Apache License, Version 2.0 (the
7 "License"); you may not use this file except in compliance
8 with the License.  You may obtain a copy of the License at
9
10   http://www.apache.org/licenses/LICENSE-2.0
11
12 Unless required by applicable law or agreed to in writing,
13 software distributed under the License is distributed on an
14 "AS IS" BASIS, WITHOUT WARRANTIES OR CONDITIONS OF ANY
15 KIND, either express or implied.  See the License for the
16 specific language governing permissions and limitations
17 under the License.
18-->
19
20# Apache OpenOffice — OpenFormula Milestone C Report
21
22## 1. Commit Information
23
24- Branch: `openformula` (rebased onto `trunk`)
25- Baseline commit: `fd13af33ac` (end of Milestone B.2)
26- Final commit: Milestone C changes (this commit)
27- Repository: <https://github.com/pgiffuni/openoffice>
28
29## 2. Source-Mining Findings
30
31### CONVERT Implementation Architecture
32
33The CONVERT function is implemented in the Analysis Add-in at
34`main/scaddins/source/analysis/analysishelper.cxx`. The architecture consists of:
35
36- **ConvertData** class: Represents a single unit with a name, conversion factor
37  (`fConst`, units per base unit), class (e.g. CDC_Pressure, CDC_Length), and
38  prefix support flag (`bPrefixSupport`).
39- **ConvertDataLinear** subclass: Handles temperature units with offset
40  (Celsius, Fahrenheit, etc.).
41- **ConvertDataList**: Maintains the registered unit table and performs
42  conversions via `ConvertDataList::Convert()`.
43- **GetMatchingLevel()**: Resolves unit names including prefix matching,
44  squared/cubed suffixes (`^2`, `^3`), and the `da`/`e` deca legacy forms.
45- **AnalysisAddIn::getConvert()**: Exposes CONVERT to the formula engine.
46
47### Key Design Observations
48
49- Conversion factors are stored as **units per base unit** (reciprocal of
50  base-units-per-unit). For pressure, base = Pascal; for length, base = Meter;
51  for area, base = m²; for volume, base = Liter.
52- Prefix exponents on squared/cubed units are multiplied by 2 or 3
53  (lines 2266-2273: "cm3" is 10⁻⁶ m³, not 10⁻² m³).
54- Binary prefixes (Table 26) are only accepted for CDC_Information class
55  (bit, byte).
56- `da` (two-char) is deca (+1), `d` (one-char) is deci (-1), `e` is legacy deca (+1).
57
58## 3. Unit-Table Comparison Against ODF 1.4 Table 24
59
60All units in ODF 1.4 Tables 24-26 were audited against the registered table.
61Categories:
62
63| Category | Count | Details |
64|----------|-------|---------|
65| Required symbols implemented correctly | Most | Pa, m, in, ft, yd, g, N, J, W, T, C, F, K, bit, byte, etc. |
66| Required symbols with corrected constants | 2 | `atm`, `Torr` (pressure constants were off) |
67| Required symbols with missing aliases | 4 | `picapt`, `pica`, `pica2`, `pica3` (Pica family) |
68| Required symbols missing entirely | 0 | All Table 24 required symbols present after fixes |
69| Prefix handling correct | Yes | All decimal prefixes (Table 25), all binary prefixes (Table 26) |
70| AOO/Excel extensions retained | Yes | All `***` marked extensions preserved |
71
72### Specific Unit Comparisons
73
74**Pressure (Table 24):**
75
76| Unit | ODF 1.4 Value | Before Fix | After Fix | Status |
77|------|--------------|------------|-----------|--------|
78| Pa | 1 Pa | 1.0 | 1.0 | Correct |
79| atm | 101325.1 Pa | 101324.996... Pa | 101325.1 Pa | Corrected |
80| at | deprecated | 101324.996... Pa | unchanged | Legacy retained |
81| SI_at | 98066.5 Pa | 98066.5 Pa | 98066.5 Pa | Already correct |
82| Torr | 101325/760 Pa | 133.32237... Pa | 133.322368... Pa | Corrected |
83
84**Pica family (Table 24):**
85
86| Unit | Definition | Before | After |
87|------|-----------|--------|-------|
88| Pica / picapt | 1/72 inch | Present (Pica only) | Present + picapt alias |
89| pica | 1/6 inch | Missing | Added |
90| Pica² / picapt² / Pica^2 / picapt^2 | (1/72 in)² | Present (Pica2) | Present + picapt2 alias |
91| pica² / pica^2 | (1/6 in)² | Missing | Added |
92| Pica³ / picapt³ / Pica^3 / picapt^3 | (1/72 in)³ | Present (Pica3) | Present + picapt3 alias |
93| pica³ / pica^3 | (1/6 in)³ | Missing | Added |
94
95## 4. Constants Changed and Their Derivation
96
97### Pressure (factors are units per Pascal)
98
99**atm:** ODF 1.4 defines 1 atm = 101325.1 Pa.
100
101- Factor = 1/101325.1 = 9.86922292699439618e-06
102- Before: 9.8692329999819300E-06 (corresponds to 101324.996... Pa)
103- Relative error before fix: ~1.0e-06
104
105**Torr:** ODF 1.4 defines 1 Torr = 101325/760 Pa.
106
107- Factor = 760/101325 = 7.50061682704169716e-03
108- Before: 7.5006380000000000E-03
109- Relative error before fix: ~2.8e-06
110
111**SI_at:** Already correct: 1/98066.5 = 1.01971621297792819e-05
112**at:** Preserved at legacy value (9.8692329999819300E-06, matches old atm).
113ODF 1.4 marks `at` as deprecated and historically ambiguous; AOO retains the
114standard-atmosphere interpretation for compatibility.
115
116### Pica family (factors are units per base unit)
117
118**Pica / picapt:** 1/72 inch = 0.0254/72 m.
119
120- Factor = 72/0.0254 = 2.83464566929133889e+03 per meter
121- Minor precision improvement from 2.8346456692913386E03.
122
123**Pica² / picapt²:** (1/72 in)² per m² = 8.03521607043214142e+06.
124**Pica³ / picapt³:** (1/72 in)³ per Liter = 2.27769904358706400e+07.
125
126**pica:** 1/6 inch = 0.0254/6 m.
127
128- Factor = 6/0.0254 = 2.36220472440944917e+02 per meter.
129
130**pica²:** (1/6 in)² per m² = 5.58001116002232156e+04.
131**pica³:** (1/6 in)³ per Liter = 1.31811287244621799e+04.
132
133## 5. Prefix Behavior Audited (Tables 25-26)
134
135**Decimal prefixes (Table 25):** All 20 prefixes (yocto through yotta)
136recognized with correct exponents. `da` = deca (+1), `d` = deci (-1),
137`e` = legacy deca (+1). No changes needed.
138
139**Binary prefixes (Table 26):** All 8 prefixes (kibi through yobi)
140recognized for CDC_Information class only (bit, byte). Rejected for other
141classes. No changes needed.
142
143**Squared/cubed prefix exponent multiplication:** Verified at lines 2266-2273.
144`cm3` → exponent ×3 (10⁻⁶ m³), `cm2` → exponent ×2 (10⁻⁴ m²). Correct.
145
146**Case sensitivity:** Unit name matching uses `equals()` which is case-sensitive.
147`ATM` ≠ `atm`. No changes needed.
148
149## 6. Tests Added to calcval-cases14.tsv
150
15121 new test cases added:
152
153**Pressure (1 case):**
154
155| ID | Formula | Expected | Purpose |
156|----|---------|----------|---------|
157| CONVERT.Torr | =CONVERT(1;"Torr";"Pa") | 133.32236842105263 | Torr = 101325/760 Pa exactly |
158
159**Pica family (15 cases):**
160
161| ID | Formula | Expected | Purpose |
162|----|---------|----------|---------|
163| CONVERT.Pica.in | =CONVERT(1;"Pica";"in") | 0.013888888888888888 | Pica point = 1/72 in |
164| CONVERT.picapt.in | =CONVERT(1;"picapt";"in") | 0.013888888888888888 | picapt alias = 1/72 in |
165| CONVERT.pica.in | =CONVERT(1;"pica";"in") | 0.16666666666666666 | Pica = 1/6 in |
166| CONVERT.Pica2.in2 | =CONVERT(1;"Pica2";"in2") | 0.00019290123456790123 | Square Pica point |
167| CONVERT.pica2.in2 | =CONVERT(1;"pica2";"in2") | 0.027777777777777776 | Square Pica |
168| CONVERT.Pica3.in3 | =CONVERT(1;"Pica3";"in3") | 0.0000026791838134430725 | Cubic Pica point |
169| CONVERT.pica3.in3 | =CONVERT(1;"pica3";"in3") | 0.004629629629629629 | Cubic Pica |
170| CONVERT.picapt2.in2 | =CONVERT(1;"picapt2";"in2") | 0.00019290123456790123 | picapt2 alias = square Pica point |
171| CONVERT.picapt3.in3 | =CONVERT(1;"picapt3";"in3") | 0.0000026791838134430725 | picapt3 alias = cubic Pica point |
172| CONVERT.Pica^2.in2 | =CONVERT(1;"Pica^2";"in2") | 0.00019290123456790123 | caret exponent spelling Pica^2 |
173| CONVERT.picapt^2.in2 | =CONVERT(1;"picapt^2";"in2") | 0.00019290123456790123 | caret exponent spelling picapt^2 |
174| CONVERT.pica^2.in2 | =CONVERT(1;"pica^2";"in2") | 0.027777777777777776 | caret exponent spelling pica^2 |
175| CONVERT.Pica^3.in3 | =CONVERT(1;"Pica^3";"in3") | 0.0000026791838134430725 | caret exponent spelling Pica^3 |
176| CONVERT.picapt^3.in3 | =CONVERT(1;"picapt^3";"in3") | 0.0000026791838134430725 | caret exponent spelling picapt^3 |
177| CONVERT.pica^3.in3 | =CONVERT(1;"pica^3";"in3") | 0.004629629629629629 | caret exponent spelling pica^3 |
178
179**Prefixes (3 cases):**
180
181| ID | Formula | Expected | Purpose |
182|----|---------|----------|---------|
183| CONVERT.km.m | =CONVERT(1;"km";"m") | 1000 | Decimal prefix |
184| CONVERT.cm2.m2 | =CONVERT(1;"cm2";"m2") | 0.0001 | Centi on squared unit |
185| CONVERT.Kibyte.bit | =CONVERT(1;"Kibyte";"bit") | 8192 | Binary prefix |
186
187**Invalid conversions (2 cases):**
188
189| ID | Formula | Expected | Purpose |
190|----|---------|----------|---------|
191| CONVERT.km.Pa | =CONVERT(1;"km";"Pa") | #ERR | Different unit groups |
192| CONVERT.ATM.Pa | =CONVERT(1;"ATM";"Pa") | #ERR | Case-sensitive unit names |
193
194## 7. Static Checks Performed
195
196- Brace balance: 0 for analysishelper.cxx
197- All fConst values verified by independent Python computation
198- Pica point factor matches existing value within precision improvement
199- Pica²/Pica³ factors match existing values within precision improvement
200- atm/Torr corrections use exact ODF 1.4 definitions (101325.1 Pa, 101325/760 Pa)
201- Pica/pica factors derived from exact inch definition (0.0254 m, exact)
202- Test expected values independently calculated from unit definitions
203
204## 8. Build and Test Status
205
206**No build or runtime tests were executed.** Per milestone instructions:
207
208- The AOO `sc` and `scaddins` modules are not configured for build in this
209  environment (no `Module_*.mk` makefiles, no generated build tree).
210- `dmake` cannot build without the gbuild configure step.
211- The calcval test harness requires a built office and runs on macOS.
212
213**For validation in a configured AOO build environment:**
214
2151. Configure AOO (`autogen.sh`/`configure`, then `build.pl --all`)
2162. Build the `scaddins` module (Analysis Add-in)
2173. Run `test/odf-validate/start.sh calcval <port>` and
218   `test/odf-validate/runpy.sh calcval.py <port> calcval-cases14.tsv <out.json>`
219   on macOS, then `python3 -I calcval.py --compare ...`
220
221## 9. Milestone B Report Correction
222
223The B.2 section of the Milestone B report previously stated that B.2 added six
224test cases. B.2 actually added four cases relative to B.1:
225
226- IFNA.ref.text, IFNA.range, SKEW.text, SKEW.err (4 cases, not 6).
227The B.1 baseline had IFNA.ref and SKEWP.two (2 cases).
228
229## 10. Remaining Known Deviations
230
231- **Build/runtime validation deferred:** No execution of the new CONVERT tests
232  against a built office was possible in this environment.
233- **`at` deprecated unit:** Retained at legacy standard-atmosphere value
234  (9.8692329999819300E-06 units/Pa) for Excel compatibility. ODF 1.4 marks it
235  as deprecated/ambiguous; no redefinition was made.
236- **Pica precision:** Pica point factor updated from 2.8346456692913386E03 to
237  2.83464566929133889E03 (full double precision of 72/0.0254). This is a
238  precision improvement, not a semantic change.
239
240## 11. Normative vs Implementation Choices
241
242| Aspect | ODF 1.4 Normative | AOO Implementation |
243|--------|-------------------|-------------------|
244| atm = 101325.1 Pa | Mandatory | Corrected to match |
245| Torr = 101325/760 Pa | Mandatory | Corrected to match |
246| SI_at = 98066.5 Pa | Mandatory | Already matched |
247| at = deprecated | Optional/legacy | Retained at standard-atmosphere value |
248| Pica/picapt = 1/72 in | Mandatory | Implemented |
249| pica = 1/6 in | Mandatory | Implemented |
250| Pica²/pica² etc. | Mandatory | Implemented |
251| Decimal prefixes | Mandatory | Implemented |
252| Binary prefixes on bit/byte | Mandatory | Implemented |
253| Case-sensitive unit names | Mandatory | Implemented |
254| Extension units (`***`) | Not specified | Retained for compatibility |
255